{"id":229,"date":"2015-12-04T15:24:02","date_gmt":"2015-12-04T15:24:02","guid":{"rendered":"http:\/\/www.climatech.at\/?page_id=229"},"modified":"2020-03-31T07:43:41","modified_gmt":"2020-03-31T07:43:41","slug":"supply-ventilation-system-operating-theatres","status":"publish","type":"page","link":"https:\/\/www.climatech.at\/en\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/","title":{"rendered":"Supply ventilation system for operating theatres"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_one_third-9497bbf8bff73ea4c6992cc17fa9ec36\">\n.flex_column.av-av_one_third-9497bbf8bff73ea4c6992cc17fa9ec36{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_one_third-9497bbf8bff73ea4c6992cc17fa9ec36 av_one_third  avia-builder-el-0  el_before_av_two_third  avia-builder-el-first  first flex_column_div av-zero-column-padding  '     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_image-3218b01322a98a8dbc4460cae5446e35\">\n.avia-image-container.av-av_image-3218b01322a98a8dbc4460cae5446e35 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-av_image-3218b01322a98a8dbc4460cae5446e35 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-av_image-3218b01322a98a8dbc4460cae5446e35 av-styling- av-hover-grow avia-align-center  avia-builder-el-1  avia-builder-el-no-sibling '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-215 avia-img-lazy-loading-not-215 avia_image ' src=\"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/ot.jpg\" alt='' title='ot'  height=\"523\" width=\"800\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/ot.jpg 800w, https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/ot-300x196.jpg 300w, https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/ot-705x461.jpg 705w, https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/ot-450x294.jpg 450w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/div><\/div><\/div><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_two_third-9c1d454dc06f7247226bc4e8f931daae\">\n.flex_column.av-av_two_third-9c1d454dc06f7247226bc4e8f931daae{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_two_third-9c1d454dc06f7247226bc4e8f931daae av_two_third  avia-builder-el-2  el_after_av_one_third  el_before_av_one_full  flex_column_div av-zero-column-padding  '     ><section  class='av_textblock_section av-av_textblock-0366cc7376be6c9e82a3e9cc8987b64f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div class=\"wpb_column vc_column_container vc_col-sm-8\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<p>In the critical zones of operating theaters, especially for intensive care and isolation of patients, the intake of contaminated air must be avoided in order to protect the patient. Furthermore pleasant working conditions for the medical team are essential to secure its optimum efficiency.<\/p>\n<p>To achieve this goal, we provide complete systems for hygienic components, as to comply in all respect with the norms and standards (DIN 1946 sheet 4, \u00d6NORM H 6020, Fed.Std. 209, VDI 2083).<\/p>\n<ul>\n<li>OT Supply-ceiling with supporting flow outlets \u2013 clean air JET\u2013OPS<\/li>\n<li>OT Supply-laminar flow ceiling \u2013 clean air LAM\u2013OPL<\/li>\n<li>OT Supply-laminar flow ceiling \u2013 clean air FLOW\u2013CAV<\/li>\n<li>OT Supply-laminar flow ceiling with exhaust unit \u2013 clean air MAX\u2013OPLF<\/li>\n<li>OT Hygienic outlet \u2013 clean air HYG\u2013HA<\/li>\n<li>OT Exhaust air fluff separator \u2013 clean air EXH\u2013OPFA<\/li>\n<\/ul>\n<p>All components are made of stainless steel, easy to clean and resistant against disinfectants.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/section><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_one_full-9497bbf8bff73ea4c6992cc17fa9ec36\">\n.flex_column.av-av_one_full-9497bbf8bff73ea4c6992cc17fa9ec36{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-av_one_full-9497bbf8bff73ea4c6992cc17fa9ec36 av_one_full  avia-builder-el-4  el_after_av_two_third  avia-builder-el-last  first flex_column_div av-zero-column-padding  column-top-margin'     ><section  class='av_textblock_section av-av_textblock-0366cc7376be6c9e82a3e9cc8987b64f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div class=\"vc_row wpb_row wf-container\">\n<div class=\"wpb_column vc_column_container vc_col-sm-12\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<p><strong>Application<\/strong><\/p>\n<p>The major objectives of room air technology in operating theatres are:<\/p>\n<ul>\n<li>Screening of the operating zone and other neighboring sterile areas against bacteriological and gaseous contaminations<\/li>\n<li>Generation of a comfort climate for the operating team and the patient<\/li>\n<li>Guarantee the required air flow between the rooms<\/li>\n<li>Air contamination will be removed from the critical operating zone and from the entire operating area<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/section><br \/>\n<div  class='togglecontainer av-av_toggle_container-8e0c6e39d39b619a829887bd54fff3ed  avia-builder-el-6  el_after_av_textblock  avia-builder-el-last  toggle_close_all' >\n<section class='av_toggle_section av-av_toggle-2144d4e068cf90c7f23299e5a3132800'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-1' data-fake-id='#toggle-id-1' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-1' data-slide-speed=\"200\" data-title=\"Clean air LAM\u2013OPL\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air LAM\u2013OPL\" data-aria_expanded=\"Click to collapse: Clean air LAM\u2013OPL\">Clean air LAM\u2013OPL<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-1' aria-labelledby='toggle-toggle-id-1' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Low-turbulence, homogeny displacement air flow<\/strong><\/p>\n<p>The ventilation system OPL generates a stable, low-turbulence displacement air flow (\u201claminar flow\u201c) in the area of the operation slab. This system prevents contamination with room-air. A variant in design is the Octaeder-\/round form.<\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-av_toggle-7e878db89c7221366f3eac1a0aca5ccc'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-2' data-fake-id='#toggle-id-2' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-2' data-slide-speed=\"200\" data-title=\"Clean air MAX\u2013OPLF\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air MAX\u2013OPLF\" data-aria_expanded=\"Click to collapse: Clean air MAX\u2013OPLF\">Clean air MAX\u2013OPLF<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-2' aria-labelledby='toggle-toggle-id-2' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Laminar-flow displacement air flow with integrated exhaust unit<\/strong><\/p>\n<p>A system for operating theatres with special high demands of hygiene and germ poverty. A stable \u201claminar\u201d air flow protects the OT-Area and provides a continuous flow around the OT-Table, team and patient. Fresh air will be mixed with OT-Return air and conditioned in a separate air handling unit. The return is sucked from the OT through grilles.<\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-av_toggle-c143926148d1e07203932fdfd13034d2'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-3' data-fake-id='#toggle-id-3' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-3' data-slide-speed=\"200\" data-title=\"Clean air JET\u2013OPS\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air JET\u2013OPS\" data-aria_expanded=\"Click to collapse: Clean air JET\u2013OPS\">Clean air JET\u2013OPS<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-3' aria-labelledby='toggle-toggle-id-3' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Low-turbulence displacement air flow with displacement area<\/strong><\/p>\n<p>The ceiling with supporting air stream generates a stable, low turbulence and draught-free displacement air flow. The stabilizing action of the supporting streams attains a wide active area, mostly with downward movement of supply air, and safely covers the operating slab, the operating team and the instrument carrier.<\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-av_toggle-4ce81b12923f80d4343f50575eaa217b'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-4' data-fake-id='#toggle-id-4' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-4' data-slide-speed=\"200\" data-title=\"Clean air HYG\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air HYG\" data-aria_expanded=\"Click to collapse: Clean air HYG\">Clean air HYG<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-4' aria-labelledby='toggle-toggle-id-4' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Turbulent mixed-airing<\/strong><\/p>\n<p>An air distribution-system, which operates according to low-turbulence induction principle. Designed for OT-rooms with low-limited room-height or special-roofing, in which no other OT suspended ceiling air-distribution system can be used. The hygienic-outlet can be used for OT-associated-adjoining rooms, as well.<\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-av_toggle-116c4f5580e4352b103dcc12b668a1dc'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-5' data-fake-id='#toggle-id-5' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-5' data-slide-speed=\"200\" data-title=\"Clean air EXH\u2013OPFA\" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air EXH\u2013OPFA\" data-aria_expanded=\"Click to collapse: Clean air EXH\u2013OPFA\">Clean air EXH\u2013OPFA<span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-5' aria-labelledby='toggle-toggle-id-5' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Exhaust air fluff-separator<\/strong><\/p>\n<p>By the use of OT linen and clothes, fluffs are generated. This is critical in OT rooms and for the connected air conditioning systems. By using fluff-grilles with removable stainless steel mesh, the contamination of exhaust and supply air will be avoided.<\/p>\n<\/div><\/div><\/div><\/section>\n<section class='av_toggle_section av-av_toggle-b0ce7e65e0e1bd01238ae0edf57c1e34'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div role=\"tablist\" class=\"single_toggle\" data-tags=\"{All} \"  ><p id='toggle-toggle-id-6' data-fake-id='#toggle-id-6' class='toggler  av-title-above '  itemprop=\"headline\"  role='tab' tabindex='0' aria-controls='toggle-id-6' data-slide-speed=\"200\" data-title=\"Clean air FLOW\u2013CAV \" data-title-open=\"\" data-aria_collapsed=\"Click to expand: Clean air FLOW\u2013CAV \" data-aria_expanded=\"Click to collapse: Clean air FLOW\u2013CAV \">Clean air FLOW\u2013CAV <span class=\"toggle_icon\"><span class=\"vert_icon\"><\/span><span class=\"hor_icon\"><\/span><\/span><\/p><div id='toggle-id-6' aria-labelledby='toggle-toggle-id-6' role='region' class='toggle_wrap  av-title-above'  ><div class='toggle_content invers-color '  itemprop=\"text\" ><p><strong>Low-turbulence, laminar displacement air flow<\/strong><\/p>\n<p>A large ceiling system for operating theatres, which ensures aseptic environment and allows any operating table positioning.<\/p>\n<\/div><\/div><\/div><\/section>\n<\/div><\/p><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":41,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-229","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Supply ventilation system for operating theatres | Clima Tech<\/title>\n<meta name=\"description\" content=\"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.climatech.at\/en\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Supply ventilation system for operating theatres | Clima Tech\" \/>\n<meta property=\"og:description\" content=\"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.climatech.at\/en\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/\" \/>\n<meta property=\"og:site_name\" content=\"Clima Tech\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-31T07:43:41+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/supply-ventilation-system-operating-theatres\\\/\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/supply-ventilation-system-operating-theatres\\\/\",\"name\":\"Supply ventilation system for operating theatres | Clima Tech\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#website\"},\"datePublished\":\"2015-12-04T15:24:02+00:00\",\"dateModified\":\"2020-03-31T07:43:41+00:00\",\"description\":\"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/supply-ventilation-system-operating-theatres\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/supply-ventilation-system-operating-theatres\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/supply-ventilation-system-operating-theatres\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.climatech.at\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hygienic applications\",\"item\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MultiCLEAN\",\"item\":\"https:\\\/\\\/www.climatech.at\\\/hygienic-applications\\\/multiclean\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Supply ventilation system for operating theatres\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#website\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/\",\"name\":\"Clima Tech\",\"description\":\"Airconditioners GmbH\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.climatech.at\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#organization\",\"name\":\"Clima Tech\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.climatech.at\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/logo.png\",\"width\":152,\"height\":100,\"caption\":\"Clima Tech\"},\"image\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Supply ventilation system for operating theatres | Clima Tech","description":"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.climatech.at\/en\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/","og_locale":"en_GB","og_type":"article","og_title":"Supply ventilation system for operating theatres | Clima Tech","og_description":"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.","og_url":"https:\/\/www.climatech.at\/en\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/","og_site_name":"Clima Tech","article_modified_time":"2020-03-31T07:43:41+00:00","twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/","url":"https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/","name":"Supply ventilation system for operating theatres | Clima Tech","isPartOf":{"@id":"https:\/\/www.climatech.at\/#website"},"datePublished":"2015-12-04T15:24:02+00:00","dateModified":"2020-03-31T07:43:41+00:00","description":"MultiCLEAN ventilation system for operating theaters is ideal for intensive care and isolation, removal of air contamination, general comfort climate.","breadcrumb":{"@id":"https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/supply-ventilation-system-operating-theatres\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.climatech.at\/"},{"@type":"ListItem","position":2,"name":"Hygienic applications","item":"https:\/\/www.climatech.at\/hygienic-applications\/"},{"@type":"ListItem","position":3,"name":"MultiCLEAN","item":"https:\/\/www.climatech.at\/hygienic-applications\/multiclean\/"},{"@type":"ListItem","position":4,"name":"Supply ventilation system for operating theatres"}]},{"@type":"WebSite","@id":"https:\/\/www.climatech.at\/#website","url":"https:\/\/www.climatech.at\/","name":"Clima Tech","description":"Airconditioners GmbH","publisher":{"@id":"https:\/\/www.climatech.at\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.climatech.at\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.climatech.at\/#organization","name":"Clima Tech","url":"https:\/\/www.climatech.at\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.climatech.at\/#\/schema\/logo\/image\/","url":"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/logo.png","contentUrl":"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/logo.png","width":152,"height":100,"caption":"Clima Tech"},"image":{"@id":"https:\/\/www.climatech.at\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/pages\/229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/comments?post=229"}],"version-history":[{"count":7,"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/pages\/229\/revisions"}],"predecessor-version":[{"id":236,"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/pages\/229\/revisions\/236"}],"up":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/pages\/41"}],"wp:attachment":[{"href":"https:\/\/www.climatech.at\/en\/wp-json\/wp\/v2\/media?parent=229"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}