{"id":30,"date":"2015-12-03T10:21:25","date_gmt":"2015-12-03T10:21:25","guid":{"rendered":"http:\/\/www.climatech.at\/?page_id=30"},"modified":"2025-01-16T10:33:04","modified_gmt":"2025-01-16T10:33:04","slug":"multicent-coolenergy","status":"publish","type":"page","link":"https:\/\/www.climatech.at\/de\/air-handling-units\/multicent-coolenergy\/","title":{"rendered":"multiCENT coolEnergy"},"content":{"rendered":"<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-58uei-feef50b38d9d451d8fc3f3eb649b2274\">\n.flex_column.av-58uei-feef50b38d9d451d8fc3f3eb649b2274{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-58uei-feef50b38d9d451d8fc3f3eb649b2274 av_one_third  avia-builder-el-0  el_before_av_one_third  avia-builder-el-first  first flex_column_div av-animated-generic pop-up av-zero-column-padding'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-4b6d6-1d334f9971f4f3ffa8c157efbfe3a1e9\">\n.iconbox.av-4b6d6-1d334f9971f4f3ffa8c157efbfe3a1e9 .iconbox_icon{\nbackground-color:#00b4c4;\nborder:1px solid #00b4c4;\ncolor:#ffffff;\n}\n.iconbox.av-4b6d6-1d334f9971f4f3ffa8c157efbfe3a1e9 .iconbox_icon.avia-svg-icon svg:first-child{\nfill:#ffffff;\nstroke:#ffffff;\n}\n<\/style>\n<article  class='iconbox iconbox_top av-4b6d6-1d334f9971f4f3ffa8c157efbfe3a1e9 av-no-box  avia-builder-el-1  avia-builder-el-no-sibling'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class=\"iconbox_content\"><header class=\"entry-content-header\" aria-label=\"Icon: Fully equipped air handling units\"><div class='iconbox_icon heading-color avia-iconfont avia-font-fontello' data-av_icon='\ue951' data-av_iconfont='fontello'  ><\/div><h3 class='iconbox_content_title'  itemprop=\"headline\" >Vollst\u00e4ndig ausgestattete L\u00fcftungsanlagen<\/h3><\/header><div class='iconbox_content_container'  itemprop=\"text\" ><\/div><\/div><footer class=\"entry-footer\"><\/footer><\/article><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-3qede-1cb151a84845b820911b85ead3ed1827\">\n.flex_column.av-3qede-1cb151a84845b820911b85ead3ed1827{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-3qede-1cb151a84845b820911b85ead3ed1827 av_one_third  avia-builder-el-2  el_after_av_one_third  el_before_av_one_third  flex_column_div av-animated-generic pop-up av-zero-column-padding'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-3bjyi-b129c7bd40d539d6fdb5cb804d454bf5\">\n.iconbox.av-3bjyi-b129c7bd40d539d6fdb5cb804d454bf5 .iconbox_icon{\nbackground-color:#00b4c4;\nborder:1px solid #00b4c4;\ncolor:#ffffff;\n}\n.iconbox.av-3bjyi-b129c7bd40d539d6fdb5cb804d454bf5 .iconbox_icon.avia-svg-icon svg:first-child{\nfill:#ffffff;\nstroke:#ffffff;\n}\n<\/style>\n<article  class='iconbox iconbox_top av-3bjyi-b129c7bd40d539d6fdb5cb804d454bf5 av-no-box  avia-builder-el-3  avia-builder-el-no-sibling'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class=\"iconbox_content\"><header class=\"entry-content-header\" aria-label=\"Icon: Integrated refrigeration plant, electrical cabinet and control system\"><div class='iconbox_icon heading-color avia-iconfont avia-font-fontello' data-av_icon='\ue884' data-av_iconfont='fontello'  ><\/div><h3 class='iconbox_content_title'  itemprop=\"headline\" >Integrierte K\u00fchlanlage, Schaltschrank und Steuerungssystem<\/h3><\/header><div class='iconbox_content_container'  itemprop=\"text\" ><\/div><\/div><footer class=\"entry-footer\"><\/footer><\/article><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2vh3m-64fe542c43629304f0099081a8c07c61\">\n.flex_column.av-2vh3m-64fe542c43629304f0099081a8c07c61{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n<\/style>\n<div  class='flex_column av-2vh3m-64fe542c43629304f0099081a8c07c61 av_one_third  avia-builder-el-4  el_after_av_one_third  el_before_av_hr  flex_column_div av-animated-generic pop-up av-zero-column-padding'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-20vpm-57e4329fa6ea6c914eeb1ba4d6bc4986\">\n.iconbox.av-20vpm-57e4329fa6ea6c914eeb1ba4d6bc4986 .iconbox_icon{\nbackground-color:#00b4c4;\nborder:1px solid #00b4c4;\ncolor:#ffffff;\n}\n.iconbox.av-20vpm-57e4329fa6ea6c914eeb1ba4d6bc4986 .iconbox_icon.avia-svg-icon svg:first-child{\nfill:#ffffff;\nstroke:#ffffff;\n}\n<\/style>\n<article  class='iconbox iconbox_top av-20vpm-57e4329fa6ea6c914eeb1ba4d6bc4986 av-no-box  avia-builder-el-5  avia-builder-el-no-sibling'  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class=\"iconbox_content\"><header class=\"entry-content-header\" aria-label=\"Icon: For plants without chilled water supply\"><div class='iconbox_icon heading-color avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue8cd' data-av_iconfont='entypo-fontello'  ><\/div><h3 class='iconbox_content_title'  itemprop=\"headline\" >F\u00fcr Anlagen ohne Kaltwasserversorgung<\/h3><\/header><div class='iconbox_content_container'  itemprop=\"text\" ><\/div><\/div><footer class=\"entry-footer\"><\/footer><\/article><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-1b792-5effd350542905e226c7ca35151e3879\">\n#top .hr.hr-invisible.av-1b792-5effd350542905e226c7ca35151e3879{\nheight:30px;\n}\n<\/style>\n<div  class='hr av-1b792-5effd350542905e226c7ca35151e3879 hr-invisible  avia-builder-el-6  el_after_av_one_third  el_before_av_textblock'><span class='hr-inner'><span class=\"hr-inner-style\"><\/span><\/span><\/div>\n<section  class='av_textblock_section av-160wq-54a19940b6d262c2a04cd37be8818287'   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><div class=\"vc_row wpb_row wf-container\">\n<div class=\"wpb_column vc_column_container vc_col-sm-12\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element\">\n<div class=\"wpb_wrapper\">\n<h4>Entwurf der Konstruktion<\/h4>\n<p>Die \"Cool Energy\"-L\u00fcftungsger\u00e4te werden mit Doppelrohrsystem, Plattenw\u00e4rmetauscher oder Energier\u00fcckgewinnungsrad kombiniert und erm\u00f6glichen eine energiesparende W\u00e4rmer\u00fcckgewinnung. Dadurch kann die Effizienz der K\u00e4lteanlage stark gesteigert werden.<br \/>\nIn der K\u00fchlsaison kann diese Kombination zur Energier\u00fcckgewinnung (Vork\u00fchlung) genutzt werden.<br \/>\nDer K\u00e4ltemittelverfl\u00fcssiger kann als luftgek\u00fchlter Abluftverfl\u00fcssiger, wassergek\u00fchlter Verfl\u00fcssiger oder als abgesetzter Verfl\u00fcssiger f\u00fcr die Au\u00dfenaufstellung ausgef\u00fchrt werden.<br \/>\nVorgesehene K\u00e4ltemittel sind R407C oder R134a, andere wie R404A, R410A sind auf Anfrage erh\u00e4ltlich.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vc_row wpb_row wf-container\">\n<div class=\"wpb_column vc_column_container vc_col-sm-12\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element\">\n<div class=\"wpb_wrapper\">\n<h4>Kombinierte Zu- und Abluftanlage<\/h4>\n<p>- Schlauchfilter<br \/>\n- Plattenw\u00e4rmetauscher zur Energier\u00fcckgewinnung (Vorw\u00e4rmung im Winter und Vork\u00fchlung im Sommer)<br \/>\n- PHW-Erhitzer<br \/>\n- luftgek\u00fchlter Verfl\u00fcssiger in der Abluft<br \/>\n- L\u00fcftersektionen als Hochleistungsl\u00fcfter ohne Spiralgeh\u00e4use<br \/>\n- K\u00e4ltesektion mit zwei Scrollverdichtern<br \/>\n- eingebauter Schaltschrank und Steuerungssystem<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vc_row wpb_row wf-container\">\n<div class=\"wpb_column vc_column_container vc_col-sm-12\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element\">\n<div class=\"wpb_wrapper\">\n<h4>K\u00e4ltesystem<\/h4>\n<p>Das K\u00e4ltesystem wird mit einem oder zwei unabh\u00e4ngigen K\u00e4ltekreisl\u00e4ufen und mit einem bis vier Verdichtern ausgef\u00fchrt. Je nach Bedarf k\u00f6nnen die K\u00e4ltekreisl\u00e4ufe mit Hei\u00dfgas-Bypass-Regelung, Verfl\u00fcssigerleistungsregelung, Fl\u00fcssigkeitssammler oder als reversible W\u00e4rmepumpe ausgestattet werden.<\/p>\n<p><u>Nur K\u00fchlung des K\u00fchlkreislaufs:<\/u><br \/>\nmit luftgek\u00fchltem Verfl\u00fcssiger in der Abluft, einem K\u00e4ltemittelkreislauf mit zwei Scrollverdichtern und indirekter Hei\u00dfgas-Bypass-Leistungsregelung als Elektroventil f\u00fcr Signal 0 bis 10 V.<\/p>\n<p><u>K\u00fchlkreislauf K\u00fchlen und Heizen:<\/u><br \/>\nmit luftgek\u00fchltem Verfl\u00fcssiger in der Abluft, einem K\u00e4ltemittelkreislauf mit zwei Scrollverdichtern als reversible W\u00e4rmepumpe.<\/p>\n<p>Die K\u00e4lteanlage ist mit folgenden Leistungs- und Verdichterausf\u00fchrungen ausgestattet:<\/p>\n<p><strong>Scroll-Verdichter<\/strong><br \/>\nIn hermetischer Ausf\u00fchrung mit sauggek\u00fchltem Motor, Motorschutz, Kurbelwannenheizung und Kipphebelventilen. Option: elektronischer Sanftanlasser zur Reduzierung des Anlaufstroms.<\/p>\n<p><strong>Hubkolbenkompressor<\/strong><br \/>\nIn halbhermetischer Ausf\u00fchrung mit sauggek\u00fchltem Motor, Motorschutz, \u00d6lpumpe und \u00d6ldruckschalter, Kurbelwannenheizung, Kipphebelventilen und Leistungsregelung durch Zylinderabschaltung. Option: elektronischer Sanftanlasser zur Reduzierung des Anlaufstroms.<\/p>\n<p><strong>Schraubenkompressor<\/strong><br \/>\nIn halbhermetischer Ausf\u00fchrung mit sauggek\u00fchltem Motor, Motorschutz, \u00d6lheizung, Kipphebelventilen und Leistungsregelung. Option: elektronischer Softstarter zur Reduzierung des Anlaufstroms.<\/p>\n<p><strong>Turbocor-Verdichter<\/strong><br \/>\nAls halbhermetischer zweistufiger Zentrifugalverdichter, \u00f6lfrei mit elektromagnetischen Lagern, Leistungsregelung durch Drehzahlregelung im Bereich von 18000 bis 48000 U\/min. Maximale Wirtschaftlichkeit im Teillastbetrieb. Sanftanlasser serienm\u00e4\u00dfig mit einem Anlaufstrom von weniger als 5A.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"vc_row wpb_row wf-container\">\n<div class=\"wpb_column vc_column_container vc_col-sm-12\">\n<div class=\"wpb_wrapper\">\n<div class=\"wpb_text_column wpb_content_element\">\n<div class=\"wpb_wrapper\">\n<h4>Elektrischer Schrank<\/h4>\n<p>Im Ger\u00e4terahmen integriert, komplett mit Ventilatordrehzahlregelung, Befeuchtersteuerung, Temperatur- und Feuchteregelung. Mit Hauptschalter, allen notwendigen Sicherungen, Motorschutzschaltern, Sch\u00fctz usw. auf Klemmen verdrahtet.<\/p>\n<h4>Betriebsvorrichtung und Mikroprozessor-Steuerungssystem<\/h4>\n<p>Programmierbares Mikroprozessor-Steuerungssystem mit allen notwendigen analogen und digitalen Ein- und Ausg\u00e4ngen. Kommunikation \u00fcber ModBus, BACnet oder \u00fcber GSM-Modem. Bedienger\u00e4t als grafisches Touchscreen-Display.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/section>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lz6oat78-f9ebbad6d20dbe11c5144a421ebf49e8\">\n#top .flex_column.av-lz6oat78-f9ebbad6d20dbe11c5144a421ebf49e8{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n.flex_column.av-lz6oat78-f9ebbad6d20dbe11c5144a421ebf49e8{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n.responsive #top #wrap_all .flex_column.av-lz6oat78-f9ebbad6d20dbe11c5144a421ebf49e8{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n<\/style>\n<div  class='flex_column av-lz6oat78-f9ebbad6d20dbe11c5144a421ebf49e8 av_one_fifth  avia-builder-el-8  el_after_av_textblock  el_before_av_three_fifth  first flex_column_div av-zero-column-padding  column-top-margin'     ><\/div>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2g5ha-95f7ef804edefc0b2c21b8151f3db60a\">\n#top .flex_column.av-2g5ha-95f7ef804edefc0b2c21b8151f3db60a{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n.flex_column.av-2g5ha-95f7ef804edefc0b2c21b8151f3db60a{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n.responsive #top #wrap_all .flex_column.av-2g5ha-95f7ef804edefc0b2c21b8151f3db60a{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n<\/style>\n<div  class='flex_column av-2g5ha-95f7ef804edefc0b2c21b8151f3db60a av_three_fifth  avia-builder-el-9  el_after_av_one_fifth  el_before_av_one_fifth  flex_column_div av-zero-column-padding  column-top-margin'     ><style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-2bo26-bda5f309d784569b62e80d2d097ac8e1\">\n#top .av_textblock_section.av-2bo26-bda5f309d784569b62e80d2d097ac8e1 .avia_textblock{\ntext-align:center;\n}\n<\/style>\n<section  class='av_textblock_section av-2bo26-bda5f309d784569b62e80d2d097ac8e1'   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" ><h4 style=\"text-align: center;\">Ben\u00f6tigen Sie ein RLT-Ger\u00e4t? Klicken Sie auf die Schaltfl\u00e4che unten, um das Formular f\u00fcr die technische Auswahl herunterzuladen. Wenn Sie Hilfe ben\u00f6tigen, k\u00f6nnen Sie uns gerne kontaktieren unter <a href=\"mailto:office@climatech.at\">office@climatech.at<\/a>.<\/h4>\n<\/div><\/section><br \/>\n<div  class='avia-button-wrap av-1kb6m-be34f3048f19c09458ad1c34d0cce72b-wrap avia-button-center  avia-builder-el-11  el_after_av_textblock  avia-builder-el-last'>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-1kb6m-be34f3048f19c09458ad1c34d0cce72b\">\n#top #wrap_all .avia-button.av-1kb6m-be34f3048f19c09458ad1c34d0cce72b{\nmargin:30px 0 0 0;\n}\n<\/style>\n<a href='https:\/\/www.climatech.at\/wp-content\/uploads\/2025\/01\/AHU-Technical-Selection-Rev.-2.pdf'  class='avia-button av-1kb6m-be34f3048f19c09458ad1c34d0cce72b av-link-btn avia-icon_select-no avia-size-x-large avia-position-center avia-color-theme-color'  target=\"_blank\"  rel=\"noopener noreferrer\"  aria-label=\"AHU-Anfrage stellen\"><span class='avia_iconbox_title' >AHU-Anfrage stellen<\/span><\/a><\/div><\/p><\/div>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-qbsa-52c1f3eaf3f598a35aa224217fef7a2d\">\n#top .flex_column.av-qbsa-52c1f3eaf3f598a35aa224217fef7a2d{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n.flex_column.av-qbsa-52c1f3eaf3f598a35aa224217fef7a2d{\nborder-radius:0px 0px 0px 0px;\npadding:0px 0px 0px 0px;\n}\n.responsive #top #wrap_all .flex_column.av-qbsa-52c1f3eaf3f598a35aa224217fef7a2d{\nmargin-top:50px;\nmargin-bottom:50px;\n}\n<\/style>\n<div  class='flex_column av-qbsa-52c1f3eaf3f598a35aa224217fef7a2d av_one_fifth  avia-builder-el-12  el_after_av_three_fifth  avia-builder-el-last  flex_column_div av-zero-column-padding  column-top-margin'     ><\/div><\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":20,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-30","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech<\/title>\n<meta name=\"description\" content=\"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.climatech.at\/de\/air-handling-units\/multicent-coolenergy\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech\" \/>\n<meta property=\"og:description\" content=\"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.climatech.at\/de\/air-handling-units\/multicent-coolenergy\/\" \/>\n<meta property=\"og:site_name\" content=\"Clima Tech\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-16T10:33:04+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/multicent-coolenergy\\\/\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/multicent-coolenergy\\\/\",\"name\":\"MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#website\"},\"datePublished\":\"2015-12-03T10:21:25+00:00\",\"dateModified\":\"2025-01-16T10:33:04+00:00\",\"description\":\"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/multicent-coolenergy\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/multicent-coolenergy\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/multicent-coolenergy\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.climatech.at\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Air handling units\",\"item\":\"https:\\\/\\\/www.climatech.at\\\/air-handling-units\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"multiCENT coolEnergy\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#website\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/\",\"name\":\"Clima Tech\",\"description\":\"Airconditioners GmbH\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.climatech.at\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#organization\",\"name\":\"Clima Tech\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.climatech.at\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.climatech.at\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/logo.png\",\"width\":152,\"height\":100,\"caption\":\"Clima Tech\"},\"image\":{\"@id\":\"https:\\\/\\\/www.climatech.at\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech","description":"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.climatech.at\/de\/air-handling-units\/multicent-coolenergy\/","og_locale":"de_DE","og_type":"article","og_title":"MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech","og_description":"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency","og_url":"https:\/\/www.climatech.at\/de\/air-handling-units\/multicent-coolenergy\/","og_site_name":"Clima Tech","article_modified_time":"2025-01-16T10:33:04+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.climatech.at\/air-handling-units\/multicent-coolenergy\/","url":"https:\/\/www.climatech.at\/air-handling-units\/multicent-coolenergy\/","name":"MultiCENT coolEnergy - air handling units with energy recovery | Clima Tech","isPartOf":{"@id":"https:\/\/www.climatech.at\/#website"},"datePublished":"2015-12-03T10:21:25+00:00","dateModified":"2025-01-16T10:33:04+00:00","description":"MultiCENT coolEnergy - air handling units with energy recovery + integrated refrigeration plant, electrical cabinet and control system, for high efficiency","breadcrumb":{"@id":"https:\/\/www.climatech.at\/air-handling-units\/multicent-coolenergy\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.climatech.at\/air-handling-units\/multicent-coolenergy\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.climatech.at\/air-handling-units\/multicent-coolenergy\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.climatech.at\/"},{"@type":"ListItem","position":2,"name":"Air handling units","item":"https:\/\/www.climatech.at\/air-handling-units\/"},{"@type":"ListItem","position":3,"name":"multiCENT coolEnergy"}]},{"@type":"WebSite","@id":"https:\/\/www.climatech.at\/#website","url":"https:\/\/www.climatech.at\/","name":"Klimatechnik","description":"Airconditioners GmbH","publisher":{"@id":"https:\/\/www.climatech.at\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.climatech.at\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.climatech.at\/#organization","name":"Klimatechnik","url":"https:\/\/www.climatech.at\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.climatech.at\/#\/schema\/logo\/image\/","url":"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/logo.png","contentUrl":"https:\/\/www.climatech.at\/wp-content\/uploads\/2015\/12\/logo.png","width":152,"height":100,"caption":"Clima Tech"},"image":{"@id":"https:\/\/www.climatech.at\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/pages\/30","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/comments?post=30"}],"version-history":[{"count":13,"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/pages\/30\/revisions"}],"predecessor-version":[{"id":1411,"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/pages\/30\/revisions\/1411"}],"up":[{"embeddable":true,"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/pages\/20"}],"wp:attachment":[{"href":"https:\/\/www.climatech.at\/de\/wp-json\/wp\/v2\/media?parent=30"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}